The FDA’s waterfall diagram for design controls highlights the connection between design inputs and outputs through verification. It’s essential in the design controls process to ensure that the outputs meet the earlier specified inputs, essentially answering the question, "Did we build this device right?"

Verification can often become problematic if there is haste in defining design inputs and outputs, underlining the importance of spending adequate time during this phase to avoid issues.

Design Inputs Overview
Design inputs are described by the FDA as the foundational aspect of the design control process, crucial for establishing the basis for all subsequent design tasks and validations. These inputs define the functional and performance criteria of a device, essentially what the device is expected to do, and serve as the groundwork for the entire development effort. Commonly interchanged with terms such as "design requirements," these inputs play a critical role in dictating the overall success and functionality of the final product.

There’s a noted practice within the industry that ideally, 30% of the project timeline should be dedicated to defining design inputs. This is because poorly defined inputs are often at the core of any issues a device faces once on the market.

Defining Design Inputs
Writing effective design to inputs should be measurable and clear. They must:

  1. Use clear, objective language.
  2. Be measurable to allow for future verification.
  3. Incorporate user needs and intended uses.
  4. Cover all necessary regulatory, functional, safety, and performance requirements.

Looking at regulations, industry standards, and user needs as a starting point helps in creating robust design inputs. Anticipating how these requirements will be verified later in the development process is crucial.

Design Outputs
Design outputs are essentially the blueprints of the device, detailing all its components, materials specifications, manufacturing instructions, and more. These outputs must be detailed enough to encapsulate and prove every specified design input. Verification of outputs against inputs is crucial; if an input specifies a measurement, the output should clearly include that measurement in its documentation.

The relation between design outputs and the Device Master Record (DMR) is also vital. While design outputs represent the initial "recipe" of the device, the DMR serves as the final comprehensive guide containing all necessary information for building and testing the device.

Validation and Documentation Challenges
The process of validating that design outputs meet design inputs is integral but can become problematic if inputs were not adequately defined or if verification considerations were neglected. Poorly planned verification can lead to costly and extensive testing procedures down the line, which emphasizes the need to think ahead during the inputs and outputs definition phase.

Streamlining with Technology
Greenlight Guru offers a solution to streamline the cumbersome and often error-prone manual processes of documenting design controls with paper-based systems. Their Design Control Software is tailored specifically for medical device professionals, allowing for easy creation and management of design control objects, linked configurations and documentation. This integration not only saves time but also enhances traceability and risk management over the product lifecycle.

By utilizing advanced tools like Green Body specific QMS systems, medical device companies can significantly reduce the time spent on documentation processes and focus more on actual design and development, ensuring better adherence to regulatory requirements and enhancing overall efficiency.

In conclusion, defining clear, measurable, and comprehensive design inputs and outputs is a fundamental step in the medical device development process that cannot be overlooked. Proper planning and utilization of advanced tools can alleviate common issues faced during the verification process, ultimately leading to a more efficient path to market for innovative medical devices.

#Define #Design #Inputs #Design #Outputs

Leave a comment